Sichuan's 2027 Time-of-Use Power Pricing Draft: Peak Rates Up 60%, an Extra Two-Hour "Low-Price Window" at Midday

Deep News11-26 20:51

On November 25, the Sichuan Provincial Development and Reform Commission opened public consultation on a draft notice concerning the improvement of the province's time-of-use electricity pricing mechanism for industrial and commercial users.

The document is slated to take effect on January 1, 2027, and covers the scope of application, peak-flat-valley time periods, floating ratios, super-peak pricing, charging facilities, and profit-loss sharing, among other aspects.

These changes are highly specific and directly affect the electricity costs of every enterprise. Here is a breakdown of the four most noteworthy shifts.

Change one: The floating ratios are unchanged, but the base for calculation has moved

Under the draft, the generation price (including three spread-cost items covering compensation for coal-fired unit operating costs, the gas-power price spread, and inter-provincial power purchase differential funding) and system operation fees are subject to time-of-use floating, while transmission and distribution prices, on-grid line loss fees, and government funds and surcharges are excluded from time-of-use floating.

Peak-period prices rise 60% above flat-period prices, super-peak-period prices rise a further 20% above peak-period prices, and valley-period prices fall 60% below flat-period prices, with dynamic adjustments to follow based on spot market conditions.

Looking at the ratios alone, the plus-or-minus 60% and the additional 20% at super-peak are consistent with the policy framework in place since 2021 and do not represent an escalation. The real change lies in the floating base: transmission and distribution prices, on-grid line loss fees, and government funds and surcharges no longer float with time-of-use periods; only the generation price and system operation fees form the pool that participates in floating.

This means that even with the same "60% peak markup" label, the absolute peak-valley price spread will differ from the old policy. Previously, transmission and distribution prices also floated, amplifying the spread as a whole; now the base has narrowed, and the spread better reflects the true cost of energy and system regulation.

Enterprises can no longer simply estimate peak costs as "flat-period price x 1.6" based on past experience and need to re-examine the floating structure on their electricity bills. For companies able to shift load to valley periods, the price-spread signal remains clear, but the actual size of the spread depends on the floating base rather than the ratio alone.

Change two: Midday gains a new "valley" period, capturing a golden window for savings

In other months (January to June and September to December), peak periods run from 10:00 to 12:00 and 18:00 to 23:00; flat periods run from 8:00 to 10:00, 12:00 to 13:00, 15:00 to 18:00, and 23:00 to 2:00 the next day; valley periods run from 2:00 to 8:00 and 13:00 to 15:00.

This is the most easily overlooked time-period adjustment in the draft, yet it has the most direct impact on continuous-production enterprises. Under the old policy, midday hours in non-summer months, such as 12:00 to 17:00, were long billed at flat-period rates, with valley pricing only beginning in the evening.

The new rules shift the valley period in other months to 2:00-8:00 and 13:00-15:00, effectively carving out a two-hour low-price window at midday. Why do this? Sichuan's midday solar output is growing rapidly, and the system already faces clear absorption pressure around noon. Designating 13:00-15:00 as valley hours uses price signals to encourage enterprises to consume more electricity at midday, shifting the load curve from the evening peak toward midday.

The practical impact: if you run continuous production without stopping at midday, two of those hours will now be settled at valley prices starting in 2027, pushing costs down. Conversely, if your usage habit concentrates load in the evening peak, this adjustment offers no cushion, because the peak period remains and the price-spread structure has already changed.

Change three: Super-peak pricing now has a ceiling and is more predictable

Super-peak periods run from 20:00 to 23:00 in July and August. In other months, super-peak pricing is triggered when the maximum temperature reaches 35 degrees Celsius or above for three consecutive days and suspended when it falls below 35 degrees for three consecutive days. The super-peak time periods match those of July and August.

To help electricity users across the province plan production in advance, the daily maximum temperature will be uniformly based on the forecast maximum temperature for Chengdu three days ahead as published by the Sichuan Provincial Meteorological Bureau. In principle, total super-peak hours for the year will not exceed 260 hours. Panzhihua, Aba Prefecture, Garze Prefecture, and Liangshan Prefecture may temporarily refrain from setting super-peak periods.

The old policy's super-peak mechanism was a high-temperature trigger system: fixed super-peak periods in July and August, and activation in other months when the maximum temperature hit 35 degrees or above for three consecutive days, but with no explicit annual cap, making it hard for enterprises to lock in an approximate range for annual super-peak electricity costs.

The new rules retain flexible triggering while adding a ceiling of no more than 260 hours per year, and allow Panzhihua, Aba, Garze, and Liangshan to temporarily skip super-peak periods. The trigger standard is also narrower, uniformly based on Chengdu's forecast maximum temperature three days ahead, which is more workable than the previous vague "next three days" wording.

For enterprises, super-peak pricing is no longer a variable that can arrive at any time for an unknown duration, but a manageable cost item with a cap and a clear meteorological basis. A maximum of 260 super-peak hours per year means that even in the worst case, the extra impact of super-peak pricing is bounded.

Change four: Who must comply? 50 kVA is the dividing line, and charging piles are included

Except for electrified railway traction (including subway) and production electricity with dedicated state provisions, agency-purchased industrial and commercial users with dedicated or public transformers at 50 kVA (kW) or above must adopt peak-valley time-of-use pricing. Agency-purchased industrial and commercial users below 50 kVA (kW) may voluntarily opt in, with the choice remaining fixed for one year.

Electricity for charging facilities billed under the residential combined-meter price will be brought into the time-of-use pricing scope and billed according to the peak-flat-valley periods and floating ratios set out in the notice. Among them, operators of electric bicycle charging facilities may voluntarily choose time-of-use pricing and charge users accordingly.

Operators of charging and battery-swap facilities billed at industrial and commercial rates will charge end users based on the agency power purchase price for the corresponding voltage level, and will apply peak-valley time-of-use pricing according to the periods set out in the notice.

The boundary between mandatory and voluntary participation is clearly drawn this time: agency-purchased industrial and commercial users at 50 kVA (kW) and above are subject to mandatory implementation, while those below 50 kVA (kW) may choose voluntarily, with the choice fixed for one year. For small and micro enterprises, the policy grants the right to decide, so they can run their own numbers on whether to opt in.

For charging facilities, the approach has shifted from a one-size-fits-all inclusion to differentiated measures: charging facilities billed under the residential combined-meter price fall within the time-of-use scope; electric bicycle charging facility operators may choose voluntarily; and operators of charging and battery-swap facilities billed at industrial and commercial rates will charge end users at the agency power purchase price for the corresponding voltage level while applying peak-valley time-of-use pricing in tandem.

For investors in heavy-truck charging stations and public charging piles, this means charging stations need to schedule charging periods more precisely, or preserve profit margins by adding energy storage and guiding vehicle owners to charge during valley hours.

In summary, for industrial and commercial enterprises, several key points in this draft deserve early attention: first, check your transformer capacity and user category to determine whether you fall within the mandatory implementation scope; second, watch for the peak-valley periods for the following year published before the end of each year and plan production accordingly; third, energy-intensive and continuous-production enterprises should focus on assessing electricity costs during peak and super-peak periods; fourth, charging facility operators should pay attention to billing rules and the voluntary choice policy; and fifth, market-based users should watch for time-of-use profit-loss sharing and platform disclosures.

The document is still in the public consultation stage, and the final scope of implementation, time periods, and ratios will be subject to the officially released document. Relevant enterprises are advised to keep following subsequent announcements from the Sichuan Provincial Development and Reform Commission.

Disclaimer: Investing carries risk. This is not financial advice. The above content should not be regarded as an offer, recommendation, or solicitation on acquiring or disposing of any financial products, any associated discussions, comments, or posts by author or other users should not be considered as such either. It is solely for general information purpose only, which does not consider your own investment objectives, financial situations or needs. TTM assumes no responsibility or warranty for the accuracy and completeness of the information, investors should do their own research and may seek professional advice before investing.